Version 1 of the ImageScan DMX protocol does not apply to software version 5.0. ImageScan DMX protocol version 2 has the following values for both control modes on channels 1, 2, and 3. The remaining channels are unchanged.
Channel 1
0 - 9 Light OFF
10 - 138 Light ON (shutter open)
139 Lamp ON
140 - 202 No effect
203 - 235 Reset fixture
236 - 252 Lamp ON
253 - 255 Lamp OFF (If and only if all other channels are at 255 - hold for 5 seconds.)
Channel 2
0 - 218 Focus far -> near
219 - 255 Focus near
Channel 3
0 - 4 Image stop
5 - 94 Gobo rotation CCW slow -> fast
95 - 184 Gobo rotation CW fast -> slow
185 - 199 Image stop
200 - 249 Gobo index coarse
250 - 255 Image stop
The full protocol is available through the ImageScan Service and Support page on our web site.