Roboscan 1016 Martin RS-485 Protocol Version 1

 

Implemented from Roboscan 1020 first EPROM software version.

Address = 8 * (Fixture DIP-switch address number - 1) + X

MSB refers to Most Significant Byte
LSB refers to Least Significant Byte

 

X

Byte

Effect(s)

Legal Data

0

MSB

Color Selection

253 = White, 241 = R61, 229 = B51, 217 = G51/56,

205 = Y52, 193 = G50/55, 181 = M47/63, 169 = B46,

157 = C54, 145 = R65, 133 = O56, 121 = G49/59,

109 = Y54, 97 = P47/58, 85 = M49/65, 73 = O59

LSB

Not used

 

1

MSB

Gobo Selection

2, 14, 26, 38, 50, 62, 74, 86, 98, 110, 122, 134, 146, 158, 170, 182

LSB

Not used

 

2

MSB

Not used

 

LSB

Not used

 

3

MSB

Shutter,
Reset

0 = Light Off, 255 = Light On

1..32 = Strobe Fast.. Slow

253 = Reset Fixture

LSB

Not used

 

4

MSB

Pan Position

30..224 = Left..Right (127=Neutral)

LSB

Not used

 

5

MSB

Tilt Position

104..150 = Up..Down (127=Neutral)

LSB

Not used

 

6

MSB

Not used

 

LSB

Not used

 

7

MSB

Pan/Tilt Speed

1..64 = Fast..Slow (Step rate divider) (1 = Default)

LSB

Not used