RoboScan 804/805
DMX Protocol version 1
NOTE: The Roboscan 804/805 can only be operated via DMX-512 if using the Martin DMX-Interface.
Product selection DIP-switch | 5 |
DMX channel requirements | 5 channels |
Roboscan 804/805
|
||
DMX channel offset (Reduced DMX) |
DMXvalue | Effect |
0 | 0 - 5 6 - 252 253 - 255 |
Lamp On / Off, Reset Fixture Lamp Off Lamp On Reset fixture |
1 | 0 - 50 51 - 100 101 - 150 151 - 200 201 - 255 |
Colors White Red Blue Green Yellow' |
2 | 0 - 63 64 - 127 128 - 191 192 - 255 |
Gobos (Roboscan 805 ONLY) Open Holes Star Cone |
3 | 0 - 30 31 - 223 224 - 255 |
Pan Max Left Left -> Right (127 = Neutral) Max Right |
4 | 0 - 12 13 - 241 242 - 255 |
Tilt Max Up Up-> Down (127 = Neutral) Max Down |