805 DMX Protocol V1

RoboScan 804/805
DMX Protocol version 1

 

NOTE: The Roboscan 804/805 can only be operated via DMX-512 if using the Martin DMX-Interface. 

 

Product selection DIP-switch 5
DMX channel requirements 5 channels

 

 

Roboscan 804/805
DMX protovol version 1

DMX channel offset
(Reduced DMX)
DMXvalue Effect
0 0 - 5
6 - 252
253 - 255
Lamp On / Off, Reset Fixture
Lamp Off
Lamp On
Reset fixture
1 0 - 50
51 - 100
101 - 150
151 - 200
201 - 255
Colors
White
Red
Blue
Green
Yellow'
2 0 - 63
64 - 127
128 - 191
192 - 255
Gobos (Roboscan 805 ONLY)
Open
Holes
Star
Cone
3 0 - 30
31 - 223
224 - 255
Pan
Max Left
Left -> Right (127 = Neutral)
Max Right
4 0 - 12
13 - 241
242 - 255
Tilt
Max Up
Up-> Down (127 = Neutral)
Max Down