The LC Series is a semi-transparent, modular system of LED panels, perfect for displaying video and images. Designed for stage shows, TV studios and other commercial applications, the LC closely integrates light, video and set design, offering entirely new possibilities for staging.
Features
- Extremely bright, 1800 NITs (cd/m2)
- Unique semi-transparent design
- Genlock feature for preventing light-flicker in TV applications
- Daisy-chain set-up with DVI-D connection (up to 6 modules per link)
- Simple, familiar assembly in truss mount format
- Units can be evenly joined for a seamless image
- All-in-one solution, with no external power supplies or drivers
- Light weight modules, easy to handle, cutting cost and time
- 40 mm pixel pitch (seamless image at about 30m)
Specifications
Physical
Length: 1000 mm
Width: 105 mm
Height: 1004 mm, LC 1140
Height: 2004 mm, LC 2140
Weight: 14.3 kg, LC 1140
Weight: 19.4 kg, LC 2140
Control and Programming
Setting and addressing: DIP switch, LC Software
Photometric Data
Light source: 5 mm oval LED
Total output (max.): 1800 Cd/m2 (1800 nits) measured outside LED tubes, Ta 25° C
Resolution, one fixture: 25 x 25 pixels (LC 1140), 25 x 50 pixels (LC 2140)
Pitch (pixel center-to-center): 40 mm
Pixels per m2: 625
Red dominant wavelength: 627.5 nm ± 2.5 nm
Green dominant wavelength: 522.5 nm ± 2.5 nm
Blue dominant wavelength: 472.5 nm ± 2.5 nm
Color resolution: 14 bits per color
Viewing angle: >100° horizontal, >40° vertical at 50% intensity
Video Processing
Video signal processor: Integrated
Video signal: XGA 1024 x 768 DVI-D (digital single link), 25x25 (LC 1140) or 25x50 (LC 2140) pixels displayed
Video signal frequency: 50 or 60 Hz
Genlock: Yes (via Martin DVI buffer box)
Construction
Panel frames: Steel and aluminum
LED tubes: Acrylic
LED tubes per panel: 25
Transparency through panel (unmasked area): >60%
Color: Black panel frames
Protection rating: IP20
Installation
Orientation: Any
Panel interlocking: Prolyte CCS6 conical coupler system
Connections
Power in/out: Neutrik PowerCon
Video in/out: DVI-D single link (DVI-I dual link connectors provided)
Electrical
AC power: 100-120/200-240 V nominal, 50/60 Hz
Power supply unit: Integrated, auto-sensing multi-voltage
Main fuses: Three 5 AT (LC 1140 and LC 2140)
Typical Power and Current
LC 1140:
100 V, 50 Hz: 310 W, 3.2 A, PF 0.988
100 V, 60 Hz: 309 W, 3.2 A, PF 0.989
127 V, 50 Hz: 305 W, 2.5 A, PF 0.974
200 V, 50 Hz: 299 W, 1.6 A, PF 0.978
240 V, 50 Hz: 291 W, 1.6 A, PF 0.820
LC 2140:
100 V, 50 Hz: 627 W, 6.4 A, PF 0.995
100 V, 60 Hz: 627 W, 6.4 A, PF 0.995
127 V, 50 Hz: 612 W, 4.9 A, PF 0.987
200 V, 50 Hz: 590 W, 3.1 A, PF 0.964
240 V, 50 Hz: 584 W, 2.8 A, PF 0.875
Thermal
Cooling: Forced air (temperature-regulated, low noise)
Maximum ambient temperature (Ta max.): 40° C
Minimum ambient temperature (Ta min.): 0° C
Total heat dissipation (calculated, +/- 10%): 1060 BTU/hr. (LC 1140), 2140 BTU/hr. (LC 2140)
Acoustic
Noise level: <45 dBA for one panel at 1 m, steady state, Ta 25° C
Approvals
EU safety: EN 60825-1, EN 60950
EU EMC: EN 55022, EN 55024, EN 61000-3-2, EN 61000-3-3
US safety: ANSI/UL 60950-1
Canadian safety: CAN/CSA 60950-1-03


Included Items
Prolyte CCS6 conical couplers and threaded spigots:
User manual: 35000196
Accessories
P3 Upgrade Kit for LC 1140: 91614031
P3 Upgrade Kit for LC 2140: 91614030
3 m power cable, 12 AWG, SJT, with PowerCon NAC3FCA power input connector: 11541503
Neutrik PowerCon NAC3FCA power input connector, cable mount, blue: 05342804
Neutrik PowerCon NAC3FCB power output connector, cable mount, light grey: 05342805
Power relay cable with PowerCon connectors, 1.4 m: 11850099
Power relay cable with PowerCon connectors, 2.25 m: 11850100
Power relay cable with PowerCon connectors, 3.25 m: 11850101
DVI-D cable, 1.5 m: 91611265
DVI-D cable, 3.2 m: 91611266
DVI-D cable, 5 m: 91611267
Martin DVI buffer box, LC series: 91611269
Martin DVI splitter, 2-output: 91611280
Martin DVI splitter, 4-output: 91611290
Martin DVI splitter, 8-output: 91611281
Conical coupler (Prolyte CCS6 system): 21021150
Threaded spigot for conical coupler: 08330125
Female conical coupler socket with hole for spigot: 21021151
Half conical coupler with hole for spigot, length 44 mm: 21021152
Half conical coupler with hole for spigot, length 63 mm: 21021153
Half conical coupler without hole for spigot, length 44 mm: 26820300
Four-unit flightcase for 4 x LC 1140: 91510110
Four-unit flightcase for 4 x LC 2140: 91510040
Ordering Information
4 x LC 2140, 2 x 1 m in 4-unit flightcase with 16 couplers and 24 spigots: 90354100
4 x LC 1140, 1 x 1 m in 4-unit flightcase with 16 couplers and 24 spigots: 90354110
LC 2140, 2 x 1 m in cardboard box, with 4 conical couplers and 6 spigots: 90354120
LC 1140, 1 x 1 m in cardboard box, with 4 conical couplers and 6 spigots: 90354130
Downloads
Size | ||||
Manuals | ||||
![]() |
1.03 MB | |||
![]() |
1.15 MB | |||
![]() |
1.3 MB | |||
![]() |
1.44 MB | |||
![]() |
1.73 MB | |||
![]() |
1.24 MB | |||
Illustrations | ||||
![]() |
191 KB | |||
![]() |
409 KB | |||
![]() |
1.35 MB | |||
![]() |
6.36 MB | |||
![]() |
98.7 KB | |||
Symbols | ||||
![]() |
3.37 MB | |||
![]() |
12.6 MB | |||
![]() |
339 MB | |||
Compliances | ||||
![]() |
68.3 KB | |||
![]() |
195 KB | |||
Software | ||||
version 3.10,
updated: Jun 2018
|
12.5 MB | |||
Service Notes | ||||
LC 2140 panels have 5 A main fuses, not 10 A
![]() |
||||
New firmware for LC Panels with P3 Upgrade
![]() |
||||
![]() |
555 KB | |||
Hints And Tips | ||||
![]() |
43.4 KB | |||
![]() |
43.4 KB | |||
Correct Part Number for LC Series Half Conical Coupler
![]() |
||||
Distributing DVI for LC Video Panels
![]() |
||||
Martin DVI Splitters Required for LCS Software and Genlock
![]() |
||||
Firmware | ||||
version 6A,
updated: May 2018
|
32 KB |
If any of the links above result in strange characters in your browser, please right-click the file to save it to your computer.