Last Updated: May 19
- Corrects critical DMX receive bug that could cause loss of control.
- Enables lamp sensor functions:
- If the lamp fails to strike, a lamp error (LERR) occurs. A lamp-off command must be sent before attempting to strike the lamp again.
- Pan/tilt movement stops after 1 second and lamp relay opens if there is a lamp error (LERR) after the lamp strikes due to lamp explosion, open thermal-switch, or lamp sensor failure.
- Adds CMY blackout personality setting (PERS>CMYb). When ON, color flags close 3 seconds after the dimmer to eliminate light spill.
- Adds variable fan speed regulation option (UTIL>FANS>VREG) that controls all fans. NOTE: USE ONLY WITH 200 - 260 V MAIN SUPPLIES.
- Lamp power reduces to 700W after 10 seconds if dimmer is closed (E-ballast only).
- Optimizes base fan voltage for quieter operation.
- Adds lamp temperature readout under INFO>TEMP>LAMP.
- Improves movement of prism and iris in tracking mode.
- Improves speed of indexed prism rotation.
- Corrects bug that caused dimmer to open momentarily during serial reset with DRES set to OFF.